Configuration Manager 2012, Deployment, Logs, MDT, System Center, Task Sequence, Windows 7, Windows Preinstallation Environment

Failed to run the action: Use Toolkit Package – Error: 80070002; Source: Windows

Error:

Failed to run the action: Use Toolkit Package.
The system cannot find the file specified. (Error: 80070002; Source: Windows)

Use Toolkit Package Error 80070002

Environment:

System Centre 2012 R2 CU5 Integrated with MDT 2013. Deployment Windows 7 SP1 with Office 2013.

Cause:

If the Drive Letter task sequence variable is configured to True. This does not occur if it is configured to False.

Solution:

To work around this issue, create the following two Task Sequence variables at the very top of the Task Sequence:

SMSTSDownloadRetryCount = 5
SMSTSDownloadRetryDelay = 15

Place them immediately after the Execute Task Sequence group.